: Bag filter 300 µm
: Dynamic suction inlet with magnet. h 70 mm
: Suction hose Ø 20 mm - 2 m.
: Exhaust pipe 40 mm - 2 m.
01: The dirty emulsion enters the TOS through a bag filter that removes any floating chips
02: After filtration, the dirty fluid rises upwards from the bottom of the tank: The choice of loading the TOS in this manner prevents excessive re-mixing of the fluid and avoids the formation of foam
03: When the fluid reaches the top of the first chamber, it spills toward the second chamber where the coalescing filter is fitted
04: The coalescing filter in the second chamber separates the foreign oil that collects on the surface
05: The clean emulsion remains at the bottom and fills the third chamber of the TOS
06: After passing through the third chamber, the emulsion can be returned to the machine tool tank
07: When a thick layer of foreign oil has accumulated on the surface of the second chamber, it can be conveyed to the discharge tank connected to the canister
: Extends the life of the emulsion
: Can be used on several machine tools
: Does not require operator supervision
: Reducing chemical biological risks
: Reduces fumes generated by foreign oils
: No bad odours